Fragen zum Produkt "Druckwächter 901 Prescal®"

Pressure switch 901 Prescal®
adjustable from -700 mbar to 12 bar

Applications
- Wastewater technology
- liquid level measurement
- pump control
- medical technology
- and many more
Downloads
Adjustable pressure switch monitoring overpressure, vacuum or differential pressure of liquid and gaseous – also aggressive – media.
The pressure switch uses a scaled adjustment knob to enable the adjustment of trip and reset pressure without the use of a screwdriver.
Mounting in any position, to be specified for settings below 100 mbar.
Technische Daten
Setting ranges:
Type | Setting range for upper switching point between | Maximum positive working pressure Standard/extended |
Maximum negative working pressure Standard/extended |
901.61 | 5 and 20 mbar | 0,5/4 bar | –/–1 bar |
901.62 | 10 and 50 mbar | 0,5/4 bar | –/–1 bar |
901.63 | 25 and 100 mbar | 0,5/4 bar | –/–1 bar |
901.64 | 50 and 250 mbar | 1/4 bar | –/–1 bar |
901.65 | 100 and 500 mbar | 1/4 bar | –/–1 bar |
901.66 | 250 and 1.000 mbar | 10 bar | –1 bar |
901.67 | 500 and 1.500 mbar | 10 bar | –1 bar |
901.68 | 1.000 and 3.000 mbar | 10 bar | –1 bar |
901.91 | 1,0 and 6,0 bar | 25 bar | –1 bar |
901.92 | 4,0 and 9,0 bar | 25 bar | –1 bar |
901.93 | 7,0 and 12,0 bar | 25 bar | –1 bar |
901.71 | – 5 and – 20 mbar | 0,5/4 bar | –1 bar |
901.72 | – 10 and – 50 mbar | 0,5/4 bar | –1 bar |
901.73 | – 25 and – 100 mbar | 0,5/4 bar | –1 bar |
901.74 | – 50 and – 125 mbar | 0,5/4 bar | –1 bar |
901.75 | – 75 and – 200 mbar | 1/4 bar | –1 bar |
901.76 | – 100 and – 300 mbar | 1/4 bar | –1 bar |
901.77 | – 200 and – 500 mbar | 1/4 bar | –1 bar |
901.78 | – 300 and – 700 mbar | 1/4 bar | –1 bar |
901.81 | 5 and 20 mbar (differential pressure) | 100 mbar | –100 mbar |
901.82 | 10 and 50 mbar (differential pressure) | 100 mbar | –100 mbar |
Temperature range:
Ambient temperature from –20°C to 85°C
Temperature of media up to 85°C or 130°C depending on material of pressure connection and diaphragm.
Diaphragm material:
Depending on media NBR, Silicone, FKM (Viton®), EPDM. For 901.8x Silicone, others upon request.
Pressure connection:
Material: PA, PVDF, PPS, Brass, Stainless steel
Hose nipple: 5,0mm, 6,5mm, 10,0mm
Thread: M10x1, G1/8, G1/4, G1/2
Electrical rating:
Specification of the maximum values for ohmic load.
AgNi-contact:
6(1,5) A/250 VAC
2 A/24 VDC
Gilded contact:
100 mA/24 VAC
30 mA/24 VDC
On request AgNi contacts up to 10 A / 250 VAC can also be supplied.
Electrical connection:
AMP flat plug 6.3 x 0.8 mm according to DIN 46244
Protection class:
IP44 / IP54 / IP65 depending on the used protection cap
Arrangement of contacts: